Low Density Cartridge Heaters – Sensor Options

/Tempco/Data-Assets/02-Cartridge-Images/WebC049.jpg

Type TJ1 and TK1: Grounded at Disc End

The thermocouple junction is grounded to the sheath at the disc end and packed with MgO. The concave end disc is filled with silver solder and ground flat. When inserted into a flat end blind hole, it will provide fast responsive temperature readings. Widely used in Hot Runner mold probes.

/Tempco/Data-Assets/02-Cartridge-Images/WebC050.jpg

Type TJ2 and TK2: Ungrounded at Disc End

The thermocouple junction is ungrounded, located at the end of the heater section, 1/8″ behind the end disc, and packed with MgO. Only provides reference temperature reading of the part being heated – slower response.

/Tempco/Data-Assets/02-Cartridge-Images/WebC051.jpg

Type TJ3 and TK3: Ungrounded at Center

The thermocouple junction is ungrounded and is located in the center of the length and diameter of the cartridge heater. It provides internal temperature readings of the heater core. Generally used for research applications and is not recommended for controlling process temperatures.

/Tempco/Data-Assets/02-Cartridge-Images/WebC052.jpg

Type TJ4 and TK4: Grounded at Center

The thermocouple junction is grounded to the sheath in a 1/2″ unheated section located in the center of the cartridge length unless otherwise specified. It provides good temperature readings with quick responses.

/Tempco/Data-Assets/02-Cartridge-Images/WebC053.jpg

Type TJ5 and TK5: Grounded at Lead End

The thermocouple junction is grounded to the sheath at the lead end. A minimum of 3/8″ of the cold section is required. It provides good temperature readings with quick responses.

 

Excel Automation Inc.