Low-profile 10-32 button terminals with binding head screws. Same location and minimum width requirements as types T1, T2 and T3. 6-32 threads available.
Type B1: Terminals at opposite ends (see T1) Type B2: Terminals same end (see T2) Type B3: Terminals same end (shown)
Type L1: Flexible Lead Wires at Top
Flexible lead wire exiting from the top through a brass eyelet. 10″ long leads standard; if longer leads are required, specify. Minimum Width required is 7/8″.
Type L2: Flexible Lead Wire at Heater End
Flexible lead wire exiting same end. 10″ long leads standard; if longer leads are required, specify. Minimum Width required is 1-1/8″.
Type L3: Flexible Lead Wire at Each End
Flexible lead wire exiting at opposite ends. 10″ long leads standard; if longer leads are required, specify. Minimum Width required is 3/4″.
Type R1: Armor Cable at Top
Armor cable provides far superior protection to lead wires where abrasion is a constant problem. Available with two- or three-prong plugs. 10″ of armor cable over 12″ leads is standard. If longer cable, leads or plugs are required, specify. Minimum Width required is 1″. Type R1A: Galvanized cable, crimped Type R1B: Stainless Steel cable, crimped Type R1C: Galvanized cable, tack welded Type R1D: Stainless Steel cable, tack welded Type R1E: Galvanized cable, full silver brazing Type R1F: Stainless Steel, full silver brazing
Type R2: Right-Angle Armor Cable at Top
Right-angle armor cable can be positioned in any direction. 10″ of armor cable over 12″ leads is standard. If longer leads are required, specify. Minimum Width required is 1-1/4″. Type R2A: Galvanized cable, crimped Type R2B: Stainless Steel cable, crimped Type R2C: Plain leads, no cable
Type T1: Screw Terminals at each end
Screw terminals at opposite ends.
Minimum Width required is 7/8″
Type T2: Screw Terminals at one end
Screw terminals tandem at one end.
Minimum Width required is 7/8″
Type T3: Screw Terminals at one end
Screw terminals parallel at one end.
Minimum Width required is 2″
Type W1: Wire Braid at Top
Wire braid leads offer sharp bending not possible with armor cable. 10″ of wire braid over 12″ leads is standard. If longer braid or leads are required, specify. Minimum Width required is 7/8″.
Type W2: Wire Braid at Heater End
Flexible stainless steel braided lead wires exiting at same end. 10″ stainless steel braid over 12″ leads is standard. If longer braid or leads are required, specify. Minimum Width required is 1-1/8″.
Type W3: Wire Braid at Each End
Flexible stainless steel braided lead wires exiting at opposite ends. 10″ stainless steel braid over 12″ leads is standard. If longer braid or leads are required, specify. Minimum Width required is 3/4″.
Eagle Sensors & Controls is an authorized Tempco distributor. Contact us for sales and application support.
We use cookies to optimize our website and our service.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.