Item | Specifications | ||
---|---|---|---|
Rated pressure range | 0 to 1 MPa (gauge pressure) | ||
Rated operating voltage | 24V DC±10% | ||
Power consumption | 1.5 W or less | ||
Pulse output | Open drain output ・Max. inflow current : 50mA ・Applied voltage : 24V DC or less ・Residual voltage: 1.5 V or less (at inflow current 50 mA) |
||
Output mode | Direct flow pulse | ||
Over current protection | Equipped | ||
Pulse output time | Duty(1:1) 50/100/125/250/500ms (select in setting mode) |
||
Analog current output | Output current: 4 to 20 mA Output accuracy: ±0.1 mA Max. external load: 400 Ω or less |
||
Output mode | Instant flow, air pressure and temperature (select in setting mode) |
||
Instant flow | Zero point: 4 mA (Direct flow display mode, reverse flow ~ within low flow cut off) 12 mA (Direct/Reverse flow display mode, within low flow cut off) |
||
Air pressure | 0 kPa: 4 mA, 1 MPa: 20 mA | ||
Temperature | −10℃ +14 ℉ : 4mA, +60℃ +140 ℉ : 20mA | ||
Pressure loss | Extremely small (same as straight pipe) | ||
Response time | 500ms | ||
Using environment | Enclosure protection | IP64(IEC) | |
Ambient temperature | −10 to +60℃ +14 to +140 ℉ (Storage: -20 to +70 ℃ -4 to +158 ℉) |
||
Ambient humidity | 90 % RH or less (No dew condensation or icing allowed) |
* | When installing the monitor in a horizontal pipe, install it with its display facing up. It can also be installed to vertical pipings. |
---|
Individual specifications
Small pipe size type
Model No. | AEWA2025 | AEWA2032 | |
---|---|---|---|
Pipe size | 25A (1B) | 32A (1 1/4B) | |
Measurable fluids | Air (compressed air), Nitrogen gas | ||
Flow range (actual flow) | −0.6 to −35m3/h or +0.6 to +35m3/h |
−1.1 to −65m3/h or +1.1 to +65m3/h |
|
Flow measuring accuracy | ±5%R.S. | −0.6 to −3.5m3/h or +0.6 to +3.5m3/h |
−1.1 to −6.5m3/h or +1.1 to +6.5m3/h |
±2%R.S. | −3.5 to −35m3/h or +3.5 to +35m3/h |
−6.5 to −65m3/h or +6.5 to +65m3/h |
|
Conversion accuracy | ±2.5%R.S.〔at dry air or nitrogen gas (at 90 % RH or below), ordinary temperatures and 0.5 MPa〕 | ||
Unit for pulse output | 10 / 100 / 1,000 [L/pulse] | ||
Low flow cut off | Within ±0.1m3/h | Within ±0.2m3/h | |
Material | Measuring pipe: Aluminum alloy, PPS and FVMQ | ||
Net weight | 1.5kg approx. | 1.4kg approx. | |
Accessories | M4 hexagon wrench: 1 pc |
* | With supply pressure 0.7 MPa and temperature in pipe 25 ℃ 77 °F |
---|
Medium pipe size type
Model No. | AEWA2040 | AEWA2050 | AEWA2065 | AEWA2080 | |
---|---|---|---|---|---|
Pipe size | 40A (1 1/2B) | 50A (2B) | 65A (2 1/2B) | 80A (3B) | |
Measurable fluids | Air (compressed air), Nitrogen gas | ||||
Flow range (actual flow) |
−1.3 to −80m3/h or +1.3 to +80m3/h |
−2.5 to −150m3/h or +2.5 to +150m3/h |
−4 to −240m3/h or +4 to +240m3/h |
−5 to −300m3/h or +5 to +300m3/h |
|
Flow measuring accuracy | ±5%R.S. | −1.3 to −8m3/h or +1.3 to +8m3/h |
−2.5 to −15m3/h or +2.5 to +15m3/h |
−4 to −24m3/h or +4 to +24m3/h |
-5 to −30m3/h or +5 to +30m3/h |
±2%R.S. | −8 to −80m3/h or +8 to +80m3/h |
−15 to −150m3/h or +15 to +150m3/h |
−24 to −240m3/h or +24 to +240m3/h |
−30 to −300m3/h or +30 to +300m3/h |
|
Conversion accuracy | ±2.5%R.S.〔at dry air or nitrogen gas (at 90 % RH or below), ordinary temperatures and 0.5 MPa]〕 | ||||
Unit for pulse output | 10 / 100 / 1,000 [L/pulse] | ||||
Low flow cut off | Within ±0.2m3/h | Within ±0.4m3/h | Within ±0.6m3/h | Within ±0.8m3/h | |
Material | Measuring pipe: Aluminum alloy, PPS and FVMQ | ||||
Net weight | 1.0kg approx. | 1.2kg approx. | 1.4kg approx. | 1.7kg approx. | |
Accessories | Positioning collar: 4 pcs, M4 hexagon wrench: 1 pc, Flange packing: 2 pcs, Bolt set: 1 set (bolt, nut and plain washer) |
* | With supply pressure 0.7 MPa and temperature in pipe 25 ℃ 77 °F |
---|
Large pipe size type
Model No. | AEWA2100 | AEWA2150 | AEWA2200 | |
---|---|---|---|---|
Pipe size | 100A (4B) | 150A (6B) | 200A (8B) | |
Measurable fluid | Air (compressed air) | |||
Flow range (actual flow) |
−10 to −500m3/h or +10 to +500m3/h |
−24 to −1,200m3/h or +24 to +1,200m3/h |
−40 to −2,000m3/h or +40 to +2,000m3/h |
|
Flow measuring accuracy | ±5%R.S. | −10 to −50m3/h or +10 to +50m3/h |
−24 to −120m3/h or +24 to +120m3/h |
−40 to −200m3/h or +40 to +200m3/h |
±2%R.S. | −50 to −500m3/h or +50 to +500m3/h |
−120 to −1,200m3/h or +120 to +1,200m3/h |
−200 to −2,000m3/h or +200 to +2,000m3/h |
|
Conversion accuracy | ±2.0 %R.S.〔at dry air (at 90 % RH or below), ordinary temperatures and 0.3 MPa〕 | |||
Unit for pulse output | 100 / 1,000 / 10,000 [L/pulse] | |||
Low flow cut off | Within ±2.6m3/h | Within ±5.0m3/h | Within ±9.0m3/h | |
Material | Measuring pipe: Stainless alloy, PPS and FVMQ | |||
Net weight | 10.3kg approx. | 18.3kg approx. | 24.4kg approx. | |
Accessories | Positioning collar: 2 pcs, M4 hexagon wrench: 1 pc |
* | With supply pressure 0.7 MPa and temperature in pipe 25 ℃ 77 °F |
---|
Communication specifications
Item | Specifications | |
---|---|---|
Interface | Conforming to EIA-485 | |
Protocol | MODBUS(RTU) | |
Communication method | Half-duplex | |
Synchronous system | Synchronous communication method | |
Number of connected units | 115,200 bps: Max. 8 units 9,600/19,200/38,400/57,600 bps: Max. 31 units |
|
Transmission speed | 9,600/19,200/38,400/57,600/115,200 bps (select in setting mode) |
|
Transmission format | Data length | 8 bit |
Stop bit | 1 bit/2 bit | |
Parity | None/Odd number/Even number | |
Data buffer | 100 byte | |
Response time | 9,600bps: 100 to 130ms 19,200bps: 70 to 100ms 38,400bps: 50 to 80ms 57,600bps: 40 to 70ms 11,5200bps: 40 to 70ms |
|
Ending resistance | 100 Ω approx. (built-in) (select in setting mode) |