Panasonic / Sunx Fan Type lonizer ER-F

Excel Automation is an authorized distributor of Panasonic / Sunx products. Contact us with sales and application support.

Type Standard fan type Low-volume fan type
Model No. ER-F12A ER-F12SA
CE marking compliant directives EMC Directive, RoHS Directive
Charge removal time
(±1,000 V → ±100 V)
1 sec. approx. (Note 2) 1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Power supply voltage 24 V DC ±10%
Power consumption 700 mA or less 400 mA or less
Discharge method High-frequency AC method
Discharge output voltage ± 2 kV approx.
Main functions Error output, Discharge halt input
Indicators Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation amount 0.04 ppm or less (Note 2)
Ambient temperature 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage: –10℃ to +65℃ +14℉ to +149℉
Ambient humidity 35% RH to 65% RH (No dew condensation allowed),
Storage: 35% RH to 65% RH
Grounding method C (capacitor) grounding
Material Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC
Weight New weight : 790 g approx.
Accessories Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc.

 

Discontinued Products

Type Standard fan type Low-volume fan type
Model No. ER-F12 ER-F12S
Charge removal time
(±1,000 V → ±100 V)
1 sec. approx. (Note 2) 1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Power supply voltage 24 V DC ±10%
Power consumption 700 mA or less 400 mA or less
Discharge method High-frequency AC method
Discharge output voltage ±2 kV approx.
Max. fan speed 5.3 m/s (Note 3) 4.0 m/s (Note 3)
Max. fan volume 3.68 m3/min. 2.50 m3/min.
Error output NPN open-collector transistor
• Max sink current: 50 mA
• Applied voltage: 30 V DC or less (between output terminal and 0 V)
• Residual voltage: 1 V or less (at input current of 50 mA)
Output operation OFF when discharge error or fan error detected
Normally ON
Short-circuit protection Incorporated
Discharge halt input Discharge halt: Short-circuited to 0 V
Discharge (operation start): Open
Indicators Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation amount 0.04 ppm or less (Note 2)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: –10 to +65 ℃ +14 to +149 ℉
Ambient humidity 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH
Grounding method C (capacitor) grounding
Material Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC
Weight 4 Main unit: 790 g approx.
Accessories Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc.