FFAF022

$614.10

Description

Sensor-specific data

Selectable measuring range 10 … 300 cm/s
Measuring range 1 10 … 150 cm/s
Setting range 1 15 … 150 cm/s
Measuring range 2 20 … 300 cm/s
Setting range 2 30 … 300 cm/s
Medium Water
Measuring error (total) 2 %
MTTFd (EN ISO 13849-1) 1,194.55 a
Switching Hysteresis 5 %
Temperature gradient 30 K